Level X2 · Breathing endurance

ALL DAY

High comfort — at the limit of perception

New respirator · Within the manufacturer's stated conditions of use

XRS badge, level X2

What it means

The resistance is at the limit of perception.

At this level the resistance stays at the limit of what a healthy adult perceives. The mask can be worn a whole day — office, school, shop, transport — without the resistance itself calling for a break. Most well-designed disposable respirators on the market fall here.

Continuous wear over a full day without imposed breaks: office, school, retail, transport, urban travel.

Specific resistance
30 – 60 Pa/(L·s⁻¹)
Comfort qualification
High comfort — at the limit of perception
Reference state
New respirator, unworn, taken out of its original packaging for the test, measured on a constant-flow bench

Where the boundary comes from

No threshold is set by convention.

The X2/X3 boundary, at 60 Pa/(L·s⁻¹), is the lower bound of the psychophysical detection threshold measured in the literature (58,8–74,5), rounded down by prudence. It is the best-supported boundary of the scale.

Origin of the six boundaries — Table 8 of XRS 001:2026

Same level, four situations

The level does not change with effort; what you feel does.

Specific resistance is invariant, so a mask keeps its level whatever the activity. But the pressure the wearer actually overcomes grows with the breathing flow, and the work of breathing grows with its square: a mask that is comfortable at rest becomes demanding in fast walking without having changed nature.

Pressure drop actually overcome in the four use profiles, level X2 (XRS 001:2026, Tables 9 to 12)
ProfileSituationBench flowΔp at X2 (Pa)
P1Rest, seated30 L/min15 – 30
P2Light to moderate activity60 L/min30 – 60
P3Sustained occupational effort95 L/min48 – 95
P4Intense, sporting effort140 L/min70 – 140

What the level does not say

How long you can actually wear the mask is the smallest of several limits. This level sets one of them.

  • Breathing enduranceSet by the resistance of the device. This is the object of the XRS scale.
  • Clogging of the filterResistance rises as particles accumulate, at a rate that depends on the working atmosphere.
  • Exhaled moistureLoads the media, alters the fit and favours microbial growth.
  • Surface hygieneThe outer surface is contaminated by deposit and by handling.
  • Fit over timeDegrades with handling and the loosening of the straps.
  • The manufacturer's instructionsPrevail over everything else — notably the NR marking limiting use to a single work shift.

The XRS level qualifies breathing comfort. It does not qualify filtration efficiency: the protection of a mask is declared separately, under the applicable standard. The level describes a new mask; it never authorizes use beyond the manufacturer's conditions.